Master's Thesis

Design and Experimental Validation of the Control and Actuation Systems of a Quasi-Passive Ankle Exoskeleton

João Maria Loução Carrilho Celestino — 2024

Key information

Authors:

João Maria Loução Carrilho Celestino (João Maria Loução Carrilho Celestino)

Supervisors:

Luis Filipe Pratas Quinto; Jorge Manuel Mateus Martins (Jorge Manuel Mateus Martins)

Published in

November 28, 2024

Abstract

Human locomotion is an energetically demanding process, and improving its efficiency has important implications for individuals with mobility impairments and those in physically demanding activities. Quasi-passive ankle exoskeletons offer a promising solution to reduce walking's metabolic cost by providing assistance during the push-off phase. This thesis details the design, implementation, and experimental validation of a control and actuation system for a quasi-passive ankle exoskeleton aimed at reducing metabolic cost through synchronized mechanical assistance. Building on previous research, the project optimizes the mechanical structure, actuation system, and control algorithm to improve performance and user integration. A literature review highlights the potential of ankle exoskeletons to decrease metabolic expenditure, emphasizing lightweight design, efficient actuation, and precise control. Biomechanical analysis of human gait and ankle kinematics informed the design, ensuring the exoskeleton mimics natural ankle movements. The prototype incorporates a novel overrunning clutch mechanism actuated by a bistable solenoid, enabling energy storage during dorsiflexion and release during plantarflexion in synchronization with the user’s gait. Laboratory tests showed the exoskeleton stores up to 40.7% of the energy generated by the ankle during walking, with a linear torque-displacement relationship and a mean torsional stiffness of 7.5 Nm/º. The solenoid achieves switching times of 18 ms, ensuring seamless gait assistance. While the prototype demonstrates potential, limitations include the absence of inversion and eversion movements and low impact tolerance. Future work should address these issues, optimize energy efficiency, and improve component durability.

Publication details

Authors in the community:

Supervisors of this institution:

Fields of Science and Technology (FOS)

mechanical-engineering - Mechanical engineering

Publication language (ISO code)

por - Portuguese

Rights type:

Embargo lifted

Date available:

September 27, 2025

Institution name

Instituto Superior Técnico