Master's Thesis

Primary stability of stemless shoulder implants: influence of implant design and bone density

Maria Helena Vaz Pinto Líbano Monteiro — 2023

Key information

Authors:

Maria Helena Vaz Pinto Líbano Monteiro (Maria Helena Vaz Pinto Líbano Monteiro)

Supervisors:

João Orlando Marques Gameiro Folgado (João Orlando Marques Gameiro Folgado); Carlos Miguel Fernandes Quental (Carlos Quental)

Published in

November 29, 2023

Abstract

Os implantes sem haste foram introduzidos recentemente para evitar complicações relacionadas com a haste e associadas à artroplastia total anatómica do ombro. Embora as recomendações gerais incluam boa condição óssea, existe pouco conhecimento sobre o impacto da qualidade óssea no desempenho destes implantes. O objetivo deste trabalho foi avaliar a influência da densidade óssea, como métrica da qualidade do osso, na estabilidade primária de seis implantes do ombro sem haste. As distribuições de densidades de 20 indivíduos de duas faixas etárias, 20 a 40 e 60 a 80 anos, foram incluídas neste estudo. As geometrias analisadas basearam-se nos implantes Eclipse™ da Arthrex, Global Icon™ da DePuy Synthes, Sidus™ da Zimmer, Simpliciti™ da Wright, SMR® da Lima Corporate e Inhance™ da DePuy Synthes. As artroplastias do ombro foram simuladas virtualmente em Solidworks® e os modelos tridimensionais de elementos finitos foram desenvolvidos em Abaqus®, permitindo a avaliação dos micromovimentos na interface ossoimplante. As densidades mais reduzidas registadas no grupo etário 60-80 levaram a um aumento geral dos micromovimentos. As diferenças entre os grupos etários foram estatisticamente significativas para a maioria dos implantes quando foi considerada a ocorrência de osseointegração para micromovimentos inferiores a 20 µm. O mesmo não se verificou para um limite de osseointegração de 50 µm. Considerando apenas os implantes inseridos por impactação, ou seja, excluindo o Eclipse-based, o Inhance-based e o Global Icon-based tiveram o melhor desempenho e foram os menos sensíveis à densidade óssea. O Sidusbased teve o pior desempenho, mostrando ainda uma elevada sensibilidade à densidade óssea. Stemless implants were recently introduced to prevent some of the stem-related complications associated with anatomic total shoulder arthroplasty. Although general requirements for receiving these implants include good bone conditions, little knowledge exists about how bone quality affects implant performance. The goal of this study was to evaluate the influence of bone density, as a metric of bone quality, in the primary stability of six stemless shoulder implants. The density distributions of 20 subjects from two age groups, 20 to 40 and 60 to 80 years old, were included in this study. The implant designs were based on the Eclipse™ from Arthrex, Global Icon™ from DePuy Synthes, Sidus™ from Zimmer, Simpliciti™ from Wright, SMR® from Lima Corporate, and Inhance™ from DePuy Synthes. Shoulder arthroplasties were virtually simulated in Solidworks® and three-dimensional finite element models were developed in Abaqus®, enabling the assessment of micromotions at the bone-implant interface. The decreased densities observed in the 60-80 age group led to a general increase in micromotions. The differences found between age groups were statistically significant for most implants when osseointegration was considered to occur if micromotions were less than 20 µm. The same findings were not verified for an osseointegration threshold of 50 µm. Considering only the implants inserted by impaction, which results in the exclusion of the Eclipse-based, the Inhance-based and Global Icon-based had the best performance and were the least sensitive to bone density. The worst performance was registered for the Sidus-based, which also showed a high sensitivity to bone density.

Publication details

Authors in the community:

Supervisors of this institution:

RENATES TID

203840461

Degree Name

Mestrado em Engenharia Biomédica

Fields of Science and Technology (FOS)

health-biotechnology - Medical biotechnology

Keywords

  • Stemless shoulder implants
  • Primary stability
  • Micromotions
  • Bone density
  • Finite element method
  • Implantes do ombro sem haste
  • Estabilidade primária
  • Micromovimentos
  • Densidade óssea
  • Método dos elementos finitos

Publication language (ISO code)

eng - English

Rights type:

Embargo lifted

Date available:

October 6, 2024

Institution name

Instituto Superior Técnico